I NTEGRATED C IRCUITS D IVISION
Escape Sequences
An escape sequence is one or more particular
characters sent from the terminal to the modem during
the On-Line state. This is done to switch the modem
to the command state so modem commands may
be entered during a telephone line connection. The
Escape Sequence characters are typically sent to the
CPC2400E
Then:
a. If one of the recognized AT commands is received
before the timer expires, the timer is stopped, the
command is executed and its result code is sent to
the terminal.
other modems as data.
b. If any other data is received while the timer is
An escape sequence should not occur accidentally
during an exchange of data between two modems.
Unfortunately, it is impossible to guarantee any escape
sequence will never occur naturally since there are no
restrictions on the data or timing between characters
sent between two modems during the On-Line state.
The only method of switching form the On-Line state
to the Command state that does not ever occur
naturally during an exchange of data is the Data
Terminal Ready signal (the &D1 command). The
terminal has complete control of this signal and it is
not part of the data exchanged between the modems.
The Hayes escape sequence was adopted by many
modem manufacturers and communication programs
before Hayes was granted a patent for the escape
sequence guard times. Now the unpatented Time
Independent Escape Sequence (TIES) has gained
popularity with many modem manufacturers.
TIES Escape Sequence
running, the timer is stopped, the modem returns to
the On-Line state and the received data is sent to the
other modem.
c. If the timer expires, a confirming result code is
sent to the terminal, indicating the modem is in
the Command state. The escape character can be
changed through S-Register S2. The prompt delay
timer can be changed (in 1/50 second increments)
through S-Register S12 (see S-Registers section).
Carrier Detection
After handshaking, the modem determines if a
telephone line connection exists by detecting the
carrier signal from the other modem. If the carrier is
not detected for a long enough period of time, the
modem assumes the telephone line connection with
the other modem has been broken. The modem uses
S-register S9 to determine how long a carrier must
be present before it is “detected.” The modem uses
S-register S10 to determine how long a carrier may
not be detected before the telephone line is hung up.
TIES stands for Time Independent Escape Sequence.
TIES was developed by a number of modem
manufacturers in response to Hayes enforcing patent
rights for their escape sequence guard time patent.
The Time Independent Escape Sequence is a
sequence of 3 escape characters (+ characters by
default). Once these characters have been recognized,
the modem enters the Command state without
sending a confirming result code to the terminal and
the modem starts a prompt delay timer.
For additional information please visit our website at: www.ixysic.com
IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make
changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated
Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to
its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other
applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe
property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice.
Specification: DS-CPC2400E-R03
17
?Copyright 2012, IXYS Integrated Circuits Division
OptoMOS ? is a registered trademark of IXYS Integrated Circuits Division
All rights reserved. Printed in USA.
12/22/2012
相关PDF资料
CPF-56-ALX CONN F PLUG CRIMP TRI-SHLD RG-6
CPFI-UG88-10 CONN BNC PLUG TWIST-ON
CPFI-UG88-3 CONN BNC PLUG TWIST-ON
CPFI-UG88-4 CONN BNC PLUG TWIST-ON
CPFIUG881 CONN BNC PLUG TWIST-ON
CPFIUG882 CONN BNC PLUG TWIST-ON
CPFIUG885 CONN BNC PLUG TWIST-ON
CPFIUG892 CONN BNC JACK TWIST-ON
相关代理商/技术参数
CPC240J 功能描述:瓷片电容器 CAP DISC 24PF 1000V RoHS:否 制造商:Vishay/Cera-Mite 电容:0.01 uF 容差:20 % 电压额定值:3 kV 工作温度范围:- 25 C to + 105 C 损耗因数 DF: 端接类型:Radial 产品:High Voltage Ceramic Disc Capacitors
CPC242040SC-F 制造商:ebm-papst Inc 功能描述:DCP CONTROLLER 24V 20-40C OC AL 制造商:ebm-papst Inc 功能描述:DCP CONTROLLER 24V, 20-40C OC AL
CPC242040SC-R 制造商:ebm-papst Inc 功能描述:DCP fan controller, 24V OC alarm 20-40C
CPC243555SC-F 制造商:ebm-papst Inc 功能描述:DCP CONTROLLER 24V 35-55OC OC AL 制造商:ebm-papst Inc 功能描述:DCP CONTROLLER 24V, 35-55OC OC AL
CPC243555SC-R 制造商:ebm-papst Inc 功能描述:DCP fan controller, 24V OC alarm 35-55C
CPC250 制造商:Thomas & Betts 功能描述:2-1/2 COBRA (2.576 - 3.060) PK.25
CPC271J 制造商:CORNELL DUBILIER ELECTRONICS 功能描述:Cap Ceramic 270pF 1000V C0G 5% (19 X 4.5mm) Radial 9.5mm 125°C
CPC2907B 功能描述:RELAY OPTOMOS DPST 2A 60V 制造商:ixys integrated circuits division 系列:CPC,OptoMOS? 包装:管件 零件状态:在售 电路:DPST(2 A 形) 输出类型:AC,DC 导通电阻(最大值):150 mOhms 负载电流:2A 电压 - 输入:1.2VDC 电压 - 负载:0V ~ 60V 安装类型:表面贴装 端子类型:鸥翼型 封装/外壳:8-SOP (0.400",10.16mm 宽) 供应商器件封装:8-SOIC 继电器类型:继电器 标准包装:1